Combi HP thermostatic mixer shower
InTROducTIOn
SAFETy wARnInGS
C-006-A
INTRODUCTION
This book contains all the necessary fitting and 
operating instructions for your Triton high 
pressure thermostatic mixer shower. Please read 
them carefully.
Please read through the whole of this book 
before beginning your installation.
The installation MUST be carried out by a 
suitably competent person and in sequence of 
this instruction book.
Care taken during the installation will give a long 
and trouble free life from your mixer shower.
Thermostatic mixers will automatically maintain 
your chosen temperature, even if taps are turned 
on elsewhere in the house, and shut off if either 
the hot or cold supply fails.
For the best performance within the specified 
running pressure range a minimum flow of 
eight litres per minute should be available to 
both inlets.
The mixer shower MUST NOT be subjected to 
water temperatures above 80°C.
This mixer is designed to operate on higher 
pressure systems found in the UK up to a 
maximum of 5 bar running pressure.
The high pressure valve is suitable for modulating 
type combination boilers and multi-point hot 
water heaters. It is also suitable for thermal 
storage, unvented systems and pumped gravity 
systems.
IMPORTANT: Before installing with a gas 
instantaneous water heater, make sure it is 
capable of delivering hot water at a minimum 
switch-on flow rate of 3 litres per minute. At 
flow rates between 3 and 8 litres per minute, 
the appliance must be capable of raising the 
water temperature to a minimum of 52°C. 
The water temperature at the inlet to the mixer 
must remain relatively constant when flow rate 
adjustments are made.
Inlet connections are by compression fittings for 
15 mm copper pipe.
This valve unit is supplied with a mounting 
bracket to suit installation in a chased out cavity 
in a solid wall, a stud partition wall, dry lined wall 
or fixing to a shower cubicle or panel.
SAFETY WARNINGS
Layout and sizing of pipework MUST be such 
that when other services are used, pressures 
at the shower control inlets do not fall below 
the recommended minimum.
DO NOT choose a position where the shower 
could become frozen.
The outlet of this appliance MUST NOT be 
connected to any form of tap or fitting not 
recommended by the manufacturer.
The showerhead MUST be regularly cleaned 
to remove scale and debris.
Conveniently situated isolating valves in each 
inlet supply MUST be fitted as an 
independent method of isolating the shower 
should maintenance or servicing be necessary.
If it is intended to operate the shower in areas 
of hard water (above 200 ppm temporary 
hardness), a scale inhibitor may have to be 
fitted. For advice on the Triton scale inhibitor, 
please contact Customer Service.
Do not operate the shower outside the 
guidelines as laid out in ‘site requirements’.
a.
b.
c.
d.
e.
f.
g.
Y-002-A
Due to continuous improvement and updating, 
specification may be altered without prior notice.
Y-003-A
Replacement parts can be ordered from Customer 
Service. See ‘spare parts’ for details and part numbers.