HP kp721av Manuale Utente

Pagina di 120
Technical Reference Guide
www.hp.com
4-9
System Support
4.4  Real-Time Clock and Configuration Memory
The Real-time clock (RTC) and configuration memory (also referred to as “CMOS”) functions 
are provided by the 82801 component and is MC146818-compatible. As shown in the following 
figure, the 82801 ICH10 component provides 256 bytes of battery-backed RAM divided into two 
128-byte configuration memory areas.  The RTC uses the first 14 bytes (00-0Dh) of the standard 
memory area. All locations of the standard memory area (00-7Fh) can be directly accessed using 
conventional OUT and IN assembly language instructions through I/O ports 70h/71h, although 
the suggested method is to use the INT15 AX=E823h BIOS call. 
Figure 4 4.   Configuration Memory Map
A lithium 3-VDC battery is used for maintaining the RTC and configuration memory while the 
system is powered down. During system operation a wire-Ored circuit allows the RTC and 
configuration memory to draw power from the power supply. The battery is located in a battery 
holder on the system board and has a life expectancy of three or more years. When the battery 
has expired it is replaced with a CR2032 or equivalent 3-VDC lithium battery.
4.4.1 Clearing CMOS 
The contents of configuration memory (including the Power-On Password) can be cleared by the 
following procedure:
1. Turn off the unit.
2. Disconnect the AC power cord from the outlet and/or system unit.
3. Remove the chassis hood (cover) and insure that no LEDs on the system board are 
illuminated. 
4. On the system board, press and hold the CMOS clear button (switch SW50, colored yellow) 
for at least 5 seconds.
5. Replace the chassis hood (cover).
6. Reconnect the AC power cord to the outlet and/or system unit.
7. Turn the unit on. 
To clear only the Power-On Password refer to section 4.5.1. 
RTC Area 
(14 bytes) 
Standard Config. 
Memory Area 
(114 bytes)
Extended Config. 
Memory Area 
(128 bytes) 
00h
0Dh
0Eh
80h
FFh
7Fh
Seconds (Timer) 
Minutes (Timer) 
Seconds (Alarm) 
Hours (Alarm)
Hours (Timer) 
Minutes (Alarm) 
Day of Week 
Date of Month
Month
Year
Register A 
Register B 
Register C 
Register D 
00h
0Bh
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Dh
0Ch
82801