Serial Port 2 Connector in RS-485 Mode (CN6, 
Pin 11-20
 
 
Signal 
PIN
PIN 
Signal 
DATA+ 
11
12 
NC 
DATA- 13
14  NC 
GND 
15
16 
NC 
NC 17
18 
NC 
NC 
19
20 
NC 
 
 
2.4.18.1 Signal 
Description 
– Serial Port 2 Connector in RS-485 Mode (CN6, 
Pin 
11-20
Signal 
Signal Description 
DATA+/- 
This differential signal pair sends and receives serial data to the communication 
link.  The mode of this differential signal pair is controlled through the RTS 
register of Serial Port 2. Set the RTS register of the Serial Port 2 to LOW for 
transmitting, HIGH for receiving. 
Do not select a mode different from the one used by the connected peripheral, 
as this may damage CPU board and/or peripheral. 
The transmitter drivers in the port are short circuit protected by a thermal 
protection circuit. The circuit disables the drivers when the die temperature 
reaches 150 
°C. 
RS-422 mode is typically used in point to point communication. Data and 
control signal pairs should be terminated in the receiver end with a resistor 
matching the cable impedance (typical 100-120 
Ω). The resistors could be 
placed in the connector housing. 
RS-485 mode is typically used in multi drop applications, where more than 2 
units are communicating. The data and control signal pairs should be 
terminated in each end of the communication line with a resistor matching the 
cable impedance (typical 100-120 
Ω). Stubs to substations should be 
avoided.