Removal and replacement procedures  25 
Removal and replacement procedures 
Required tools 
You need the following items for some procedures: 
 
T-15 Torx screwdriver 
 
Flathead screwdriver 
 
Diagnostics Utility 
 
Safety considerations 
Before performing service procedures, review all the safety information. 
 
Preventing electrostatic discharge 
To prevent damaging the system, be aware of the precautions you need to follow when setting up the 
system or handling parts. A discharge of static electricity from a finger or other conductor may damage 
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the 
device. 
To prevent electrostatic damage: 
 
Avoid hand contact by transporting and storing products in static-safe containers. 
 
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. 
 
Place parts on a grounded surface before removing them from their containers. 
 
Avoid touching pins, leads, or circuitry. 
 
Always be properly grounded when touching a static-sensitive component or assembly. 
 
Symbols on equipment 
The following symbols may be placed on equipment to indicate the presence of potentially hazardous 
conditions. 
  
 
 
This symbol indicates the presence of hazardous energy circuits or electric shock 
hazards. Refer all servicing to qualified personnel. 
WARNING:
  To reduce the risk of injury from electric shock hazards, do not open this 