HP ml350 Manuale Utente

Pagina di 91
 
Removal and replacement procedures  37 
Extend the server from the rack (on page 
3. 
Remove the access panel. 
4. 
Remove the air baffle. 
 
To replace the component, reverse the removal procedure. 
 
System fans 
  
 
CAUTION:
  The system fan is a non-hot-pluggable device. 
  
Fan failures are indicated by amber LEDs located on each hot-plug fan and by the front panel internal 
health LED. When a fan failure occurs, the internal health LED illuminates red in non-redundant mode and 
amber in redundant mode. 
To remove the component:  
1. 
Power down the server (on page 
2. 
Do one of the following: 
Extend the server from the rack (on page 
3. 
Remove the access panel. 
4. 
Remove the air baffle ("
5. 
Disconnect the system fan cable from the system board.