HP procurve 2500 Manuale Utente

Pagina di 270
    204
Enhancements in Release F.02.02
New Time Synchronization Protocol Options
HP2512(config)# timesync timep
Selects TimeP
.
HP2512(config)# ip timep manual 10.28.227.141
Activates TimeP in Manual
mode
.
Figure 100.   Example of Configuring Timep for Manual Operation
Changing the TimeP Poll Interval. 
This command lets you specify how long the switch waits 
between time polling intervals. The default is 720  minutes and the range is 1 to 9999 minutes. (This 
parameter is separate from the poll interval parameter used for SNTP operation.)
Syntax:
ip timep dhcp interval < 1 . . 9999 >
ip timep manual interval < 1 . . 9999 > 
For example, to change the poll interval to 60 minutes:
HP2512(config)# ip timep interval 60
Disabling Time Synchronization Without Changing the TimeP Configuration. 
The recom-
mended method for disabling time synchronization is to use the 
timesync
 command. This halts time 
synchronization without changing your TimeP configuration.
Syntax:
no timesync
For example, suppose TimeP is running as the switch’s time synchronization protocol, with 
DHCP
 as 
the TimeP mode, and the factory-default polling interval. You would halt time synchronization with 
this command:
HP2512(config)# no timesync
If you then viewed the TimeP configuration, you would see the following:
Figure 101.   Example of TimeP with Time Sychronization Disabled