HP procurve 2500 Manuale Utente
249
Software Fixes
■
Syslog (PR_1000003656)
— The syslog capability added to F.05.22.
■
Syslog (PR_1000004080)
— A timep event log message on syslog is truncated.
■
Web (PR_81848)
— 'Clear changes' button does not work for the Default Gateway or VLAN
selections.
■
Web (PR_82039)
— If the user selects GVRP mode, selects a port and then selects nothing
as an option for the port mode, all ports below the selected port disappear. This does not
affect the switch configuration.
affect the switch configuration.
■
Web (PR_82199)
— VLAN port modification shows misleading mode. In the Configuration
- VLANs - Modify page, select a port, then set the "mode" modify pull-down menu to "tagged".
Select another port. The "mode" pulldown field remains set to "tagged", which is misleading
and incorrect, in general.
Select another port. The "mode" pulldown field remains set to "tagged", which is misleading
and incorrect, in general.
■
Web (PR_92078)
— After making changes under the Device Features tab the page never
fully loads.
■
Web/IP Stack Management (PR_92826)
— When using the Web browser interface with
a large stack of Switches, if the user moves very quickly from one option to another the Web
interface may freeze or the commander may crash with a Bus Error.
interface may freeze or the commander may crash with a Bus Error.
■
Web (PR_97407)
— During port security configuration the switch may report "Unable to
add new MAC Address. MAC entry is either a multicast, broadcast or NULL address",
regardless of the actual cause of the failure. The fix is to display a meaningful error message.
regardless of the actual cause of the failure. The fix is to display a meaningful error message.
■
Web (PR_97671)
— When trying to add more than the maximum allowed number of VLANs
the switch responds with the vague message "Commit failed".
■
Web (PR_98500)
— With Sun java 1.3.1 the browser window may spontaneously close.
■
Web (PR_1000000452)
— Resetting the Switch leads to the URL aol.co.uk.
■
Web (PR_1000001702)
— Sometimes when the user clicks on the Apply button on the
Configuration/Monitor Port screen the Switch complains, "not enough params specified".
Release F.05.23 (Not a General Release)
Fixed in release F.05.23
■
GVRP (PR_1000005082)
— Incorrect error message 'Commit Failed' when trying to add
more than the configured "max vlans" using CLI.
■
SNMP (PR_1000004345)
— The data for MIB object 'dot1dStpPortDesignatedPort' is
presented in byte-reversed order.
■
Telnet (PR_92019)
— After establishing the maximum number of telnet sessions, a session
that is closed will still be shown as active.