HP qms 1660 Manuale Utente

Pagina di 306
Timeouts
QMS 1660 Print System Reference
4-66
Timeouts
You can configure a number of printer timeout settings to set a limit to 
the amount of time the printer waits to perform a certain task.
Setting an Emulation Timeout
The emulation timeout is the maximum number of seconds emula-
tions other than PostScript (such as HP-GL, HP PCL 5, and Line-
printer) wait for incoming data.
Setting an ESP Timeout
The ESP (Emulation Sensing Processor) timeout is the maximum 
number of seconds the printer uses to match an emulation before 
Notes
If you used the Administration/Engine/Inputbin 
x Name options 
to change the names of the inputbins, these names replace 
Multipurpose, Lower, and Optional in the message window.
Menu
Administration/Communications/Timeouts/Emul Timeout
Choices
00000-99999
Default
00005 (5 sec.)
Notes
A value of 000 is the same as infinity (no timeout).
When selecting a baud rate of 2400 or below (Administration/
Communications/Serial/Baud Rate menu), increase the 
emulation timeout value as follows:
Baud Rate
Emulation Timeout (seconds)
2400
10*
1200
20
600
40
300
80
*A baud rate of 2400 works with a 5-second emulation timeout 
value, but there is no margin for delays between characters.