HP srom Manuale Utente

Pagina di 2
 
 
 
that Scan. For instance, associate only Cisco Scans with 
Cisco systems and HP Scans with HP systems. 
 
Example: To associate Scan ALPHARMC_CRITICAL 
1.  On the ConsoleWorks main menu, click  
Manage > Scans > Show Scans
2.  On the Show Scans page, in the Scans column, 
click ALPHARMC_CRITICAL
3.  On the Scan: ALPHARMC_CRITICAL page, in the 
Unassociated Consoles column, select the check 
boxes next to the names of the managed systems 
you want to associate with the Scan. 
4. Click 
Update Scan.   
For detailed instructions on associating Scans, please 
refer to the ConsoleWorks user guide.  
 
SCANS AVAILABLE IN THE HP ALPHASERVER 
RMC/SROM IEM 
 
The HP AlphaServer RMC/SROM IEM contains a 
Master Scan and five Event Severity Scans.  
Master Scan 
The Master Scan, ALPHARMC, is the top-level Scan. It 
references all the other Scans in the IEM. When you 
associate the Master Scan with an AlphaServer system, 
you are specifying that ConsoleWorks scan the data 
stream of that system for all 74 Events.  
Event Severity Scans 
The HP AlphaServer RMC/SROM IEM contains five 
Event Severity Scans. Use these Scans to monitor 
AlphaServer systems for messages based on the 
Severity level of the Events. 
The IEM provides the following Event Severity Scans: 
 
• ALPHARMC_CRITICAL 
12 
Events 
• ALPHARMC_MAJOR 
15 
Events 
• ALPHARMC_MINOR 
23 
Events 
• ALPHARMC_WARNING 
Events 
• ALPHARMC_INFORMATIONAL 
20 
Events 
 
 
 
 
 
 
 
 
SAMPLE HP ALPHASERVER RMC/SROM IEM 
EVENTS 
  
The HP AlphaServer RMC/SROM IEM provides you with 
names, message texts, Severity ratings, and causes for 
Events produced by AlphaServer systems running 
RMC/SROM firmware. 
The following section displays samples of the 
information you receive for each Event in the  
HP AlphaServer RMC/SROM IEM. 
 
Sample Event 1 
Name:   
ALPHARMC_ACLOSS 
Message: 
No AC power to the system
 
Severity: 
CRITICAL 
Cause:  
No AC power is present to the system.  
 
 
A fatal error has been detected. Most  
 
 
fatal errors prevent the system from  
  completing 
the 
power-up 
sequence. 
 
Sample Event 2 
Name:   
ALPHARMC_KBDERR  
Message: 
Keyboard not detected
 
Severity: 
INFORMATIONAL 
Cause:  
The system cannot detect a keyboard. 
 
 
 
 
© 2006 TECSys Development, Inc. The information in this document is 
provided by TECSys Development, Inc. as-is without warranty of any 
kind and is subject to change without notice. The warranties for 
TECSys Development, Inc. solutions are set forth in the limited 
warranty statements accompanying such solutions. Nothing herein 
shall be construed as constituting an additional warranty. All products 
or company names mentioned in this document are trademarks or 
registered trademarks of their respective owners. Portions of the 
technology within the ConsoleWorks server are protected under US 
Patent number 6,505,245. ConsoleWorks is a registered trademark of 
TECSys Development, Inc.