Canon GM-1000 Manuale Utente

Pagina di 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
107
Command ID 
161 
Command 
Name 
Counter Clear Timing 
Data 
0: Head 1 
1: Head 2 
Return 
Value 
Timing 0 or 1 
Explanation  It is necessary to set the return value as follows. 
Head 1 Parameter ID = 11 
Head 2 Parameter ID = 14 
These values have the standalone motor unique values, and the controller motor set 
with servo tuning at Canon has been explained. 
When changing the motor or controller, after checking this command Head 1 and Head 
2, it is necessary to make settings. 
 
E.g.:    A1C101/0 with a return value of 0, set with parameter A1P011/0. 
     
A1C101/1 with a return value of 1, set with parameter A1P014/1. 
     
A2C101/0 with a return value of 1, set with parameter A2P011/1. 
     
A2C101/1 with a return value of 0, set with parameter A2P014/0.