Nikon coolpix 4300 Manuale Di Manutenzione
VAA12901-R.3594.A
- E4300 -
The contents of inspection standards and tools for E4300
[1] Inspection standards ................................................................................................................................. R1 to R5
[2] Tools ......................................................................................................................................................... T1 to T3
[2] Tools ......................................................................................................................................................... T1 to T3
Conditions to be set and prepared for inspections
1. Physical stance to measure :
On the applicable product, its lens shall be set flat and its monitor shall be set to vertically stand up.
2. Room temperature and constantly controlled humidity :
25 ± 5℃ Relative humidity : 65 ± 20 %
3. Battery to be employed :
Primary battery:
25 ± 5℃ Relative humidity : 65 ± 20 %
3. Battery to be employed :
Primary battery:
Unless otherwise specified, us a Sanyo 2CR5 lithium battery
(within four months of manufacture).
When using various manufacturers, conduct the inspection using a Sanyo, Matsushita or Duracell
2CR5lithium battery.
2CR5lithium battery.
Secondary battery:
Use the dedicated rechargeable battery EN-EL1.
Use the dedicated rechargeable battery EN-EL1.
(Use after it has been fully charged with the dedicated AC adapter EH-21 or battery charger MH-53.)
4. Standard power supply :
Specified AC power supply EH-21 shall be required.
Specified AC power supply EH-21 shall be required.