Nikon coolpix 4300 Manuale Di Manutenzione

Pagina di 52
VAA12901-R.3594.A
- E4300 -
The contents of inspection standards and tools for E4300
[1]  Inspection standards  ................................................................................................................................. R1 to R5
[2]  Tools  ......................................................................................................................................................... T1 to T3
Conditions to be set and prepared for inspections
1. Physical stance to measure :
On the applicable product, its lens shall be set flat and its monitor shall be set to vertically stand up.
2. Room temperature and constantly controlled humidity :
   25 ± 5℃    Relative humidity : 65 ± 20 %
3. Battery to be employed :
   Primary battery:
Unless otherwise specified, us a Sanyo 2CR5 lithium battery
(within four months of manufacture).
When using various manufacturers, conduct the inspection using a Sanyo, Matsushita or Duracell 
2CR5lithium battery.
   Secondary battery:
      Use the dedicated rechargeable battery EN-EL1.
     (Use after it has been fully charged with the dedicated AC adapter EH-21 or battery charger MH-53.)
4. Standard power supply :
  Specified AC power supply EH-21 shall be required.