Replace a DC Power Supply
M40 Internet Router Hardware Guide
146
12. Slide the power cable lugs onto the terminal studs on the power supply faceplate (see 
„ Connect the positive (+) source cable lug to the return terminal, which is labeled 
RTN
.
„ Connect the negative (–) source cable lug to the input terminal, which is labeled 
–48V
.
Run the power cables to the left on the left power supply, and to the right on the right 
power supply. This arrangement enables you to replace a power supply without having 
to detach the cables from the other power supply.   
Figure 61:  Attach Cables to a DC Power Supply
13. Secure the cable lug to the terminal studs, first with locking washers, then nuts. Using a 
7/16-in. nut driver or wrench, tighten the nuts.
14. Verify that the power cabling from the source DC breaker to the power supply is correct.
There is no standard color coding for DC power cables. The 
color coding used by the external DC power source at your 
site determines the color coding for the leads on the power 
cables that attach to the circuit breaker box. You must 
ensure that the connections at the circuit breaker box 
maintain the proper polarity. The power source DC cables 
might be labeled 
(+)
 and 
(–)
 to indicate their polarity. 
.
1131
Grounding studs
Terminal studs
Input
Return
Cable lug
Locking
washers
Nuts
Do not substitute a metric nut driver or wrench. A tool that 
does not fit the nuts exactly can damage them. If a 7/16-in. 
tool is not available, use pliers or an adjustable wrench.