4. Test Procedure
4-1 List of Equipment
- DC Power Supply
- Test Jig
- Test Cable
- CDMA Mobile Station Test Set 
HP8924C, HP83236A, CMD-80, etc
- Spectrum Analyzer(include CDMA Test Mode) HP8596E
4-2 Configuration of Test
❈ CAUTION : The test jig and data cable has a voltage drop of 0.33V at FM Max power output,
you’d better set the DC power supply to 3.93V for normal test condition.
(Nominal voltage of battery is 3.6V at cellular phone)  
4-1
Spectrum Analyzer
RF In
HP8924C
RF
In/Out
Directional
Coupler
Test Jig
To A-Out
To A-In
DC Power Supply
(+3.93V)
Audio
Out
Audio
In