Sony trinitron kv-29sl40a Manuale Utente

Pagina di 71
— 29 —
KV-27S40 / 27S45 / 27S65 / 29SL40 / 29SL40A / 29SL40C/
29SL45 / 29SL65 / 29SL65C/ 29XL40M / 29XL40P / 29XT11A
5-1.  ELECTRICAL ADJUSTMENT BY REMOTE COMMANDER
7.  Press 
 then 
 on the Remote Commander to
     initialize.
Carry out step 7 when adjusting
IDs 0 to 4 and when replacing
and adjusting IC003.
SERVICE          RESET
8. Turn set off and on to exit.
(3)  Adjust Buttons and Indicator
Use Remote Commander (RM-Y167) to perform circuit
adjustments on this model.
NOTE : Test Equipment Required:
1.  Pattern Generator
2.  Frequency Counter
3.  Digital Multimeter
4.  Audio OSC
(1)  Method of Setting the Service
Adjustment Mode
  
SERVICE MODE PROCEDURE
   1.  Standby mode. (Power off)
2.
 
   
 
 
 
 on the
Remote Commander. (Press each button within a
second.)
  SERVICE  ADJUSTMENT MODE IN
3. The CRT displays the item being adjusted.
4. Press 
 or   on the Remote Commander to select the
item.
5. Press 
 or   on the Remote Commander to change the
data.
6. Press 
 then 
 to write into memory.
  SERVICE  ADJUSTMENT MODE MEMORY
                     
  
Green
SERVICE          WRITE
Red
(2)  Memory Write Confirmation Method
1.   After adjustment, pull out the plug from the AC outlet,
      then replace the plug in the AC outlet again.
2.  Turn the power switch ON and set to service mode.
3.  Call the adjusted items again to confirm they were adjusted.
            SECTION 5
CIRCUIT ADJUSTMENTS
Disp.
(Item)
Item
data
SERVICE           SYS     0
RM-Y167