REQUIRED CABLE ASSEMBLY OPTIONS:
CBL100: 20A with 12/5 cable 9’ long terminated with a NEMA L21-20P
SOLD SEPARATELY
for use in North America at 120/208V~
CBL102: 20A with 5x2.5mm Harmonized cable 9’ long. A plug is not provided
so that the end user can provide the country specific plug
for use in Europe at 230/400V~
for use in Europe at 230/400V~
SPECIFICATIONS
PC302-I/MTD
PC302-I/LT
Approvals
UL/cUL, TUV, CE
UL/cUL, TUV, CE
Voltage Input (Selectable)
120/208 VAC or 230/400 VAC
120/208 VAC or 230/400 VAC
Voltage Output Single Phase
120 VAC or 230 VAC
120 VAC or 230 VAC
Frequency (Hz)
50/60Hz
50/60Hz
Current Input Per Phase
20A or 16A Per Phase
20A or 16A Per Phase
Current Output Per Phase
16A Per Phase
16A Per Phase
Full load VA Per Phase
1920 VA or 3680 VA Per Phase
1920 VA or 3680 VA Per Phase
Main Circuit Breaker
4 Pole 20A
4 Pole 20A
IEC 60320 Outlets
Type C13
Type C13
EMI/RFI Filter
20A per phase
20A per phase
Surge Suppression
270V
270V
Power Input
Terminal Block
Terminal Block
RACK MOUNTED
•
19” x 3.4” (2U) x 8.5” with recess
mounting
mounting
•
Approximate shipping weight: 19 lbs.
EMI/RFI FILTER
•
Differential Mode
•
Common Mode
SPIKE/SURGE SUPPRESSION
•
Line to Line
VOLTAGE SELECTION SWITCH
•
Select 120/208V~ or 230/400V~ input
•
120/208V~ input with 120V~ output
•
230/400V~ input with 230V~ output
LOCAL/OFF/REMOTE SWITCHING
•
Local: “On/Off” to switched outlets
•
Off: When breaker is “on” but this switch
is in the “off” mode, you will have power
to the unswitched outlets only
is in the “off” mode, you will have power
to the unswitched outlets only
•
Remote: “On/Off” to switched outlets via
a remote control device
a remote control device
•
Latching remote, the selection switch is
wired for Remote/Off/Remote - There is
no local control on the PC302-I/LT
wired for Remote/Off/Remote - There is
no local control on the PC302-I/LT
(14) IEC 60320 TYPE C13 OUTLETS
•
12 on the front panel switched and 2 on
rear panel unswitched
rear panel unswitched
•
Rated by UL/CSA up to 250V~/15A
•
Rated by VDE at 250V/10A each
POWER INPUT
•
External terminal block for power input is
on rear panel
on rear panel
•
High Voltage Cover with attached
cable/plug is available, reference below
part numbers
cable/plug is available, reference below
part numbers
REMOTE CONTROL
•
Remote on/off and EPO control, EPO
overrides remote and local control
overrides remote and local control
•
Sequence Power Up additional
equipment down line
equipment down line
•
Latching remote - (N/C) EPO,
momentary start on PC302-I/LT only
momentary start on PC302-I/LT only
MULTIPLE TIME DELAY™ (MTD™)
•
Activated “Locally” or “Remotely”, PH-X
powers up, followed 4-seconds later by
PH-Y, which is followed 4-seconds later
PH-Z, then 4-seconds later the
sequenced remote activates the next
system in line
powers up, followed 4-seconds later by
PH-Y, which is followed 4-seconds later
PH-Z, then 4-seconds later the
sequenced remote activates the next
system in line
(6) INDICATOR LIGHTS
•
Main Power “on”
•
Power to Phase X, Y, and Z
•
120/208V~ input selected
•
230/400V~ input selected
Front
Back