4. Energy Management Calibration
 – Select Tuning –> Energy Management Calibration
 – Connect service battery to phone and dc cable
  between phone and service battery
 – Set supply voltage to 10.5 V
 – Run calibrations separately or all at once
 – Select calibrations:
  Battery & charger default values
  ––––––––––––––––––––––––––––––––
  – Select 1.Run Battery & charger default values
    checkbox
  Battery voltage
  –––––––––––––––
  – Select 2.Battery voltage checkbox
  Charger voltage
  –––––––––––––––
  – Select 3.Charger voltage checkbox
  Battery size
  ––––––––––––
  – Select 4.Battery size checkbox
  Battery temperature
  –––––––––––––––––––
  – Select 5.Battery temperature checkbox
  Charge current
  ––––––––––––––
  – Select 6.Charge current
 – Select Save without confirmation, if you don’t want
  confirm all the selected calibration values before saving
 – Run calibrations by pressing Run button
 – Set supply voltage back to 8.4 V