4. Energy Management Calibration
– Select Tuning –> Energy Management Calibration
– Connect service battery to phone and dc cable
between phone and service battery
– Set supply voltage to 10.5 V
– Run calibrations separately or all at once
– Select calibrations:
Battery & charger default values
––––––––––––––––––––––––––––––––
– Select 1.Run Battery & charger default values
checkbox
Battery voltage
–––––––––––––––
– Select 2.Battery voltage checkbox
Charger voltage
–––––––––––––––
– Select 3.Charger voltage checkbox
Battery size
––––––––––––
– Select 4.Battery size checkbox
Battery temperature
–––––––––––––––––––
– Select 5.Battery temperature checkbox
Charge current
––––––––––––––
– Select 6.Charge current
– Select Save without confirmation, if you don’t want
confirm all the selected calibration values before saving
– Run calibrations by pressing Run button
– Set supply voltage back to 8.4 V