Outdoor Unit
CU-4KS31NBU
Indoor Unit
CS-MKS9NKU ×
4
< 208V >
Remarks:
1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
 
For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                     Indoor Unit : CS-MKS9NKU   4units        Outdoor Unit : CU-4KS31NBU  1unit
2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
 
 
 
Outdoor air temp.  95 °F DB / 75 °F WB
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Compressor
Refrigerant / Amount charged at shipment
Ibs (g)
Refrigerant Control
12.7
2,560
28,600
8.40
( 9,800 to 28,600 )
( 2.90 to 8.40 )
Shipping Volume
Cooling
24,200
4,400
Net
Shipping
Package Dimensions
Weight
Height × Width × Depth
Height × Width × Depth
Ibs (kg)
Ibs (kg)
cu.ft (m
3
)
(mm)
inch
(mm)
4-Room Multi Outdoor Unit
Outdoor Unit
inch
187 to 253
 
Dimensions & Weight
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Sensible Capacity
Latent Capacity
W
Power Input
V
A
Available Voltage Range
Running Amperes
Operation Sound (High) Cool
Narrow tube
Wide tube
Refrigerant
inch (mm)
Tube Diameter
inch (mm)
174.2
183.0
(79.0)
(83.0)
(890 × 900 × 320)
Outdoor Unit
35-1/32 × 35-7/16 × 12-19/32
1/4 (6.35) × 4
3/8 (9.52) × 2 + 1/2 (12.7) × 2
ft (m)
dB-A
Max. allowable tubing length per unit
Flare Type
100 (30.5)
R410A / 8.38 (3,800)
Electric Expansion Valve
DC Twin Rotary (Inverter)
Fan Speeds
Auto (Hi, Me, Lo)
Control
Microprocessor
Features
Compressor Locked Rotor Amperes
53
BTU/h
Performance
%
Power Factor
99
A
17.0
Type
BTU/h
kW
Total Capacity
BTU/h
4
Number of Connectable Indoor Units
4
Number of Operatable Indoor Units
208V Single-Phase 60Hz
Voltage Rating
1,942 (3,300)
Air Circulation  (High)
ft
3
/min (m
3
/h)
EER
BTU/h/W
11.2
Fuse or Circuit Breaker Capacity
A
20
15.88  (0.45)
40-1/8 × 41-11/32 × 16-21/32
(1,019 × 1,050 × 423)
16