Panasonic EY6506-U1 Manuale Utente

Pagina di 8
(Refer to WIRING CONNECTION DIAGRAM)
4 TROUBLESHOOTING GUIDE
< TROUBLE >
< CHECK >
< REMEDY >
Does not operate.
<CHECK BATTERY PACK.>
NO Replace battery pack.
If no less than 12V DC is available across the (+) and (-) terminals,
the battery pack is OK.
NOTE:
The battery pack is sold separately as an optional accessory.
See the nearest sales dealer for details. The battery pack has a
limited life.
The pack should be replaced if;
- after being charged for the rated charging time the battery voltage
is less than 12V DC or the usable time is extremely short.
- the battery leaks. Check battery for leaks and terminals for
corrosion.
OK
<CHECK TERMINAL CONNECTIONS BETWEEN MAIN UNIT
NO Repair contacts.
AND BATTERY PACK.>
Check for proper terminal contacts.
OK
<CHECK SWITCH BLOCK.>
NO Contacts in switch block
(See WIRING CONNECTION DIAGRAM.)
are defective.
Check continuity between following terminals.
Replace switch & FET
* Inspection of the forward / reverse selection switch.
block.
When switch handle is depressed all the way:
- There should be 0
Ω
between (A) - (D) , and between (B) - (C) ;
when switch lever is set to forward side.
- There should be 0
Ω
between (A) - (C) , and between (B) - (D) ;
when switch lever is set to reverse side.
* Inspection of the brake.
When switch handle is not depressed:
- There should be 0
Ω
between (A) - (B) .
OK
<CHECK MOTOR BRUSH.>
NO Replace motor
A. Check the condition of carbon brush.
brush assembly.
(Do not touch between brush holder and holding spring.)
B. There should be 0
Ω
between motor lead wire and
terminal of brush holder.
OK
<CHECK MOTOR ROTOR.>
NO Replace motor
Check the condition of rotor if there is any wear, crack and deformation.
rotor assembly.
OK
<CHECK MOTOR STATOR.>
NO Replace motor
Check the condition of motor case if there is any crack and deformation.
stator.
5