Panasonic wj-fs216 Manuale Utente

Pagina di 30
-9-
2. ALARM BUZZER
The buzzer beeps when this unit receives the alarm
signal.  You can adjust the buzzer time between 1
and 60 seconds by changing the ALARM BUZZER
parameter.
1. Move the cursor to the ALARM BUZZER parameter.
2. Select the buzzer time.
OFF:
The alarm buzzer does not beep when the
alarm signal is received.
1-30, 60S:
The buzzer keeps on beeping for the
duration you set.  The letter “S” stands for sec-
onds.
The factory setting is 2S.
    * MENU 1 OF 3 *
 DYNAMIC REC     OFF
 ALARM BUZZER     2S
 ALARM OUTPUT     2S
 REC MODE       4FIELDS
2. Select the duration the alarm signal is output.
1-30, 60S:
The alarm signal is output for the dura-
tion you set. The letter “S” stands for seconds.
The factory setting is 2S.
3. ALARM OUTPUT
When alarm is received, the alarm signal is sup-
plied to the other device through the
ALARM/REMOTE connector.  You can adjust the
duration the alarm signal is output between 1 and
60 seconds.
1. Move the cursor to the ALARM OUTPUT parameter.
    * MENU 1 OF 3 *
 DYNAMIC REC     OFF
 ALARM BUZZER     2S
 ALARM OUTPUT     2S
 REC MODE       4FIELDS
2. Select the recording mode.
4-255 FIELDS:
The output signal to be recorded on
the VTR is switched each time after the number
of fields you have set.
T/L:
The recording output signal is supplied to the
VTR for time lapse recording.
The factory setting is 4 FIELDS.
Note:
When T/L is selected and no camera switching
signal supplied, there will be no correct time
lapse recording.  In this case, either supply the
camera switching signal or select 4 - 255 fields
in REC mode for normal recording.
4. REC MODE
The recording mode can be set to 4-255 fields or
time lapse recording.
1. Move the cursor to the REC MODE parameter.
    * MENU 1 OF 3 *
 DYNAMIC REC     OFF
 ALARM BUZZER     2S
 ALARM OUTPUT     2S
 REC MODE       4FIELDS