Toshiba MK1032GAX Manuale Utente

Pagina di 159
 
 
  Toshiba Corporation Digital Media Network Company 
 
Page 27 of 159 
© 2004, Copyright TOSHIBA Corporation All Rights Reserved
 
                   
11.   HOST INTERFACE 
Related Standards 
Information technology - AT Attachment Interface with Extensions (ATA-2) 
   X3T10.279-199x 
Information technology - AT Attachment-3 Interface (ATA-3) 
 
 
 
X3T10/2008D Revision 6    October 26, 1995   
Information technology - AT Attachment with Packet Interface Extension (ATA -4) 
 
 
 
T13/1153D Revision 17    October 30, 1997   
Information technology - AT Attachment with Packet Interface-5 (ATA-5) 
 
 
 
T13/1321D Revision 3      February 29, 2000 
Information technology - AT Attachment with Packet Interface-6 (ATA-6) 
 
 
 
T13/1410D Revision 3b    February 26, 2002 
 
11.1 Cabling 
 
11.1.1 Interface Connector 
 
Drive side   
     connector  
Yamaichi GAP050K11617 or equivalent   
Recommended 
host side 
connector 
for board 
straight type    : Berg 86455-044  86456-044 
                or equivalent 
 
for cable 
Berg 89361-044    or equivalent 
 
11.1.2 Cable  
 
The following table shows preferable twisted pair type of cable . 
      Standard diameter 
  0.32 mm ( 28 AWG ) 
   Characteristics impedance 
 100- 132  
Ω