Toshiba MK1032GAX Manuale Utente

Pagina di 159
 
 
  Toshiba Corporation Digital Media Network Company 
 
Page 97 of 159 
© 2004, Copyright TOSHIBA Corporation All Rights Reserved
 
                   
 
11.8.33  Read Native Max Address      (F8h) 
 
COMMAND CODE 
1 1 1 1 1 0 0 0
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
DRIVE No. 
no change 
CY 
 
maximum cylinder number 
HD 
 
maximum head number 
SN 
 
maximum sector number 
LBA  
maximum 
LBA 
 
This command sets the maximum address in CY, HD, SN register. If LBA ( DRV / HD register bit6 ) is set to 1, 
the maximum address shall be LBA value. 
 
If the 48-bit native max address is greater than 268,435,455, the Read Native Max Address command shall 
return a maximum value of 268,435,454. 
 
11.8.34  Read Native Max Address EXT      (27h) 
 
COMMAND CODE 
0 0 1 0 0 1 1 1
 
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
 
drive no. 
no change 
LBA 
Low 
Current 
Previous 
 HOB=0
HOB=1
Max LBA(7:0) 
Max LBA(31:24) 
LBA 
Mid 
Current 
Previous 
 HOB=0
HOB=1
Max LBA(15:8) 
Max LBA(39:32) 
LBA 
High 
Current 
Previous 
 HOB=0
HOB=1
Max LBA(23:16) 
Max LBA(47:40) 
SC Current 
Previous 
 HOB=0
HOB=1
no change 
no change 
FT Current 
Previous 
reserved 
reserved 
HOB=0
HOB=1
no change 
no change 
 
This command sets the maximum address (LBA value).