Toshiba MK4006GAH Manuale Utente

Pagina di 153
 
 
Toshiba Corporation Digital Media Network Company 
 
Page 119 of 153 
    © 2003, Copyright TOSHIBA Corporation All Rights Reserved
 
 
11.8.42.9  SMART Disable Operations   
 
 
COMMAND CODE 
1 0 1 1 0 0 0 0
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
DRIVE No. 
no change 
CY C24Fh 
no 
change 
HD  
no 
change 
SN  
no 
change 
SC  
no 
change 
FT D9h 
no 
change 
 
 
This command disables all SMART capabilities within the drive including any and all timer functions related 
exclusively to this function. After receipt of this command the drive may disable all SMART operations. 
Parameters for drive failure prediction will no longer be monitored or saved by the drive. The state of 
SMART (either enabled or disabled) will be preserved by the drive across power cycles. 
 
Upon receipt of the SMART DISABLE OPERATIONS command from the host, the drive sets BSY, disables 
SMART capabilities and functions, clears BSY and asserts INTRQ. 
 
After receipt of this command by the drive, all other SMART commands, except for SMART ENABLE 
OPERATIONS, are disabled and invalid and will be aborted by the drive (including SMART DISABLE 
OPERATIONS commands) with an Aborted command error. 
 
 
11.8.42.10  SMART Return Status   
 
 
COMMAND CODE 
1 0 1 1 0 0 0 0
REGISTER 
 
REGISTER SETTING 
NORMAL COMPLETION 
DR 
DRIVE No. 
no change 
CY C24Fh 
C24Fh/2CF4h 
HD  
no 
change 
SN  
no 
change 
SC  
no 
change 
FT DAh 
no 
change 
 
If an impending failure is not predicted, the drive sets the Cylinder Low register to 4Fh and the Cylinder High 
register to C2h. If an impending failure is predicted, the drive sets the Cylinder Low register to F4h and the 
Cylinder High register to 2Ch. 
 
This command is used to communicate the reliability status of the drive to the host’s request. Upon receipt of 
this command the drive sets BSY, saves any parameters monitored by the drive to non-volatile memory and 
checks the drive condition.