Toshiba MK4006GAH Manuale Utente

Pagina di 153
 
 
Toshiba Corporation Digital Media Network Company 
 
Page 32 of 153 
    © 2003, Copyright TOSHIBA Corporation All Rights Reserved 
 
11.3.3 Signal Treatment 
Driver types and requirements for the signal pull- up and down are as follows. Resistor requirement is minimum for the 
host. - IO16 is pulled up in the drive with certain value so that the Vol is obtained to run with a host that has large value of 
pull up resistor.    - CS0    and - CS1 are also pulled up for better noise immunity. 
 
Table 11.3-2  Signal treatment 
    SIGNAL 
Driven by 
TYPE 
By host 
By drive 
- RESET 
Host 
TP 
 
10kΩPU 
 DD 0:15 
bi-direction TS
 DMARQ Drive  TS
5.6 
Ω PD
- DIOR 
Host TS
-DMARDY 
 
   
HSTROBE 
 
   
- DIOW 
Host TS
STOP   
   
 IORDY 
Drive 
TS
4.7 k 
Ω PU
-DDMARDY 
 
   
DSTROBE 
 
   
 CSEL 
Host GND
10 
Ω PU
- DMACK 
Host TP
 INTRQ Drive TS
10 
Ω PD
- IOCS16 
Drive 
OD
1.0 k 
Ω PU
1.2 k 
Ω PU
 DA 0:2 
Host TP
- PDIAG/
Drive TS
10 
Ω PU
- CS0  - CS1 
Host TP
- DASP 
Drive 
OD
10 k 
Ω PU