Word clock settings
If a device such as a digital MTR or DAT recorder is digitally connected to the 
AW4416, the clock that controls the timing at which digital audio is processed 
(referred to as the “word clock”) must be synchronized. To do so, you must select 
one of the devices as the word clock master, and set the remaining devices so 
that they will follow the word clock supplied from the master device. Here we 
will explain how to select the clock source to which the AW4416 will synchro-
nize.
Be aware that if the system includes an unsynchronized device, drop-outs and 
click noise will occur.
1. Turn on the power of the external digital device and of the AW4416.
If an external device is connected to the SCSI connector of the AW4416, you 
must turn on the power in the order of external SCSI device → AW4416. If the 
power of the external SCSI device is off when you turn on the AW4416, it may 
not start up correctly.
If the D.in Setup tab is not assigned to the [F4] key when you press the [SETUP] 
key, press the [SHIFT] key + [F1] key to switch the tab, and then press the [F4] 
key.
2. 2. Press the [SETUP] key → [F4] key.
The SETUP UP screen D.in Setup page will appear, allowing you to make word 
clock settings.
In the WORD CLOCK SOURCE area of this screen you can select one of the fol-
lowing as the clock source to which the AW4416 will synchronize.
❍ SLOT 1 1/2–7/8
❍ SLOT 2 1/2–7/8
An input signal from a digital I/O card installed in OPTION I/O slot 1/2 will be 
the clock source. You can select one pair from input channels 1/2–7/8 of the digi-
tal I/O card, and the AW4416 will synchronize to the word clock data included 
in the input signal of the corresponding channel.