Electrical Requirements
Before you move your refrigerator into its final location, it is 
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded 
electrical supply is required. It is recommended that a separate 
circuit serving only your refrigerator be provided. Use an outlet 
that cannot be turned off by a switch. Do not use an 
extension cord.
NOTE: Before performing any type of installation, cleaning, or 
removing a light bulb, turn the control (Thermostat, Refrigerator or 
Freezer Control depending on the model) to OFF and then 
disconnect the refrigerator from the electrical source. When you 
are finished, reconnect the refrigerator to the electrical source and 
reset the control (Thermostat, Refrigerator or Freezer Control 
depending on the model) to the desired setting.
Water Supply Requirements
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
IMPORTANT:
If you turn the refrigerator on before the water line is 
connected, turn the ice maker OFF.
All installations must meet local plumbing code requirements.
Use copper tubing and check for leaks. Install copper tubing 
only in areas where the household temperatures will remain 
above freezing.
TOOLS NEEDED: Flat-blade screwdriver, 
⁷⁄₁₆" and ¹⁄₂" open-end 
wrenches or two adjustable wrenches, 
¹⁄₄" nut driver and drill bit, 
hand drill or electric drill (properly grounded).  
NOTE: Your refrigerator dealer has a kit available with a 
¹⁄₄" 
(6.35 mm) saddle-type shutoff valve, a union, and copper tubing. 
Before purchasing, make sure a saddle-type valve complies with 
your local plumbing codes. Do not use a piercing-type or 
³⁄₁₆" 
(4.76 mm) saddle valve which reduces water flow and clogs more 
easily.
Water Pressure
A cold water supply with water pressure of between 30 and 
120 psi (207-827 kPa) is required to operate ice maker. If you have 
questions about your water pressure, call a licensed, qualified 
plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
refrigerator needs to be between 30 and 120 psi (207 - 827 kPa)
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 - 414 kPa).
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 - 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Connect the Water Supply
(on some models)
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water line is 
connected, turn the ice maker OFF.
Connect to Water Line
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long 
enough to clear line of water.
3. Locate a 
¹⁄₂" to 1¹⁄₄" (1.27 cm to 3.18 cm) vertical cold water 
pipe near the refrigerator.
IMPORTANT:
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the 
pipe, not the bottom. This will help keep water away from 
the drill and normal sediment from collecting in the valve.
4. Determine the length of copper tubing you will need. Measure 
from the connection on lower left rear of refrigerator to the 
water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use 
¹⁄₄" 
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both 
ends of copper tubing are cut square. 
5. Using a grounded drill, drill a 
¹⁄₄" hole in the cold water pipe 
you have selected.
6. Fasten the shutoff valve to the cold water pipe with the pipe 
clamp. Be sure the outlet end is solidly in the 
¹⁄₄" drilled hole in 
the water pipe and that the washer is under the pipe clamp. 
Tighten the packing nut. Tighten the pipe clamp screws slowly 
and evenly so washer makes a watertight seal. Do not 
overtighten or you may crush the copper tubing.
7. Slip the compression sleeve and compression nut on the 
copper tubing as shown. Insert the end of the tubing into the 
outlet end squarely as far as it will go. Screw compression nut 
onto outlet end with adjustable wrench. Do not overtighten. 
8. Place the free end of the tubing in a container or sink, and turn 
ON the main water supply. Flush the tubing until water is clear. 
Turn OFF the shutoff valve on the water pipe. Coil the copper 
tubing.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
E. Compression sleeve
F. Shutoff valve
G. Packing nut
A
B
C
D
E
F
G