Tally Genicom 6600 Manuale Utente

Pagina di 330
Horizontal And Vertical Line Commands (Create)
195
Vertical Line Command
STOP
Command Terminator.
Enter STOP and the printer waits for a new 
command. Leave STOP out and the 
printer will wait for another Horizontal Line 
Command.
Table 29. Horizontal Line Command
Field
Function
Option/Modifier Selections
Table 30. Vertical Line Command
Field
Function
Option/Modifier Selections
VERT
Command Specifier.
Enter VERT
The following parameters define print location and line thickness of a vertical line. The SR, SC, 
and EC parameters control placement, length, and thickness of vertical lines on a form. Whether 
in columns or dots depends on the SCALE Command. You may also use the XX.YY format for 
plotting duplication print locations explained earlier in the Standards Section.
LT;
Dictates the line thickness.
Vertical line thickness is based on dot 
increments (1/60”), then end the entry with 
the parameter delimiter. Line thickness is 
only limited by specifications.
SC;
Plots the starting COLUMN of the 
line.
Enter a value ranging from 1 to one less 
than the maximum form width and the 
parameter delimiter.
SR;
Plots the starting ROW of the line.
Enter a value ranging from 1 to one less 
than the maximum form length and the 
parameter delimiter.
ER
Plots the ending ROW of the line.
Enter a value ranging from 2 to one less 
than the maximum form length.
STOP
Command Terminator.
Enter STOP and the printer waits for a new 
command. Leave STOP out and the 
printer will wait for another Vertical Line 
Command.