Tally Genicom 6600 Manuale Utente

Pagina di 330
234
Chapter
11
Barcode Printing
EAN/UPC Barcode
(X, Y = unregarded):
1
) These values are true, if “Compressed Print” is selected in the menu (see 
print feature [F]).
2
) It is recommended to set the bar width equal to the space width (x=y).
3
) Printer-dependent reference value.
All values are only valid when a new color ribbon is used. The values change 
depending on the degree of wear:
narrow bar: approx. -0.05 mm
narrow space: approx. +0.05 mm.
Code EAN 128 and EAN/UPC are based on module widths. Only the X 
parameter is valid for this type. This parameter is used for the Y parameter 
(narrow bar width). The Z parameter has no meaning. In combination with the 
normal/condensed feature, 8 widths result (see Table 1 on page 233).
Error Code
Wrong characters in a control code or in a barcode test (e.g. an undefined 
character in a certain barcode type) cause the barcode error sign to print.
Table 2
Header Parameter
Normal
Compressed
1
)
Enlargement
factor
z =  0
z =  1
1.95 : 1
1.60 : 1
1.30 : 1
0.95 : 1