Table 3-2. Signal Descriptions 
 
 
 
Label 
 
I/O Type 
 
Signal Name/Description 
VCC PWR 
+5 VDC. A standard 5V +/- 5% - 1.5A power supply is strictly required to 
supply this module (5V Versions). Average current is 270mA  
(350mA @ PCL5). See also chapter 5.1.2 
 
+3.-3 VDC. A standard 3.3V +/- 5% - 1A power supply is strictly required to 
supply this module (3V Versions). Average current is 270mA  
(350mA @ PCL5). See also chapter 5.1.3 
GND GND 
Digital Ground Connect to Digital Ground on the interface circuit. 
~RESET IC 
Modem Reset (ON/OFF). To be pulled to ground by external transistor for 
reset. (on module pull-up resistor of 200K). The GSM Modem has already an 
internal power-up reset circuit. Needs special timing for RESET and ON/OFF 
function (see chapter 3.8) 
AGND GND 
Analog Ground. if a microphone or headset is used, use this as a ground. If 
these are never used, it can be connected to DGND. 
 
 
 
 
 
OPTIONAL SIM CARD READER INTERFACE 
Label 
I/O Type  Signal Name/Description 
SIMCLK O 
 
SIM Clock. Provided from module. 
 
SIMRST O 
 
SIM Reset. Provided from Module to reset the SIM Card. 
 
SIMDATA I/O 
 
SIM Data line. Digital, bi-directional data line to exchange data between 
module and SIM card. 
 
SIMVCC PWR 
 
SIM Power Supply
. 3VDC Power Supply provided from module to power 
the SIM Card. Only 3V SIM Cards are supported.