LS 3070 Product Reference Guide: Setup
 
The RL 470 base station is a charger, host interface, and — significantly — 
receiving station for RF transmission. Therefore, do not install the RL 470 
inaccessibly under a table or buried in a desk drawer. At a minimum, mount 
the RL 470 on a table or desk top. For optimum RF performance, especially in 
difficult environments, mount the RL 470 on  a wall as high as possible. But 
keep in mind the limits of interface cable length and charging accessibility. 
Proper base positioning gives you the best possible range and coverage 
performance from the LS 3070 cordless scanning system.
 
Inserting the Scanner Into and Removing 
Scanner from Base/Charger
 
To insert the scanner into the base/charger:
1. First, place the nose to the scanner into the large rectangular receptacle of 
the base/charger. 
2. Then place the scanner handle into the opening of the smaller, latched 
receptacle and press down firmly until the bottom of the handle seats 
snugly into the receptacle and engages the latch. 
Caution
 
Use of excessive force in placing the scanner into the base can 
damage the charging contacts on the shoe of the scanner or in the 
receptacle of the base. Such damage can interfere with or prevent 
charging of the scanner’s batteries by the base
 
3. To remove the scanner from the base/charger, grasp the handle of the 
scanner and lift the bottom of the handle out of the latched receptacle, 
thereby freeing the scanner from the base. 
Caution
 
It is important to remove the scanner 
 
handle-first
 
. Trying to re-
move the scanner nose-first can break latch in the base receptacle