Symbol Technologies LS 3070 Manuale Utente

Pagina di 214
4-6
LS 3070 Product Reference Guide: Maintenance and Specifications
LS 3070 Standard Technical Specifications
ITEM
DESCRIPTION
Power Requirements
:
Scanner
4.75 to 14 VDC; 210 mA @ 5 VDC Typical.
Base/Charger
5 VDC ± 10% @ 190 mA Typical.
12 VDC ± 10% @ 400 mA Typical.
Scan Repetition Rate
Approximately 36 (± 3) scans/sec 
(bidirectional)
Start-up Time
<50 msec. from scan enable
Data Acquisition Time
<110 msec. from scan enable
Skew Tolerance
± 65° from normal
Pitch Angle
± 55° from normal
Decode Depth of Field
Minimum Element Width 
0.005 in.
.127 mm
Maximum Element Width
0.2 in.
5.08 mm
Print Contrast Minimum
20% absolute dark/light reflectance 
differential, measured at 675 nm.
Ambient Light Immunity
Artificial Lighting
450 ft. candles
4844 lux
Sunlight
8000 ft. candles
86112 lux (@8 in. on low 
density bar codes)
Durability
6-ft. drop to concrete
Operating Temperature
0° to 40°C
32° to 104°F
Storage Temperature
-40° to 60°C
-40° to 140°F
Humidity
5% to 95% (non-condensing)
Height
6.3 in.
16 cm
Length
5 in.
12.7 cm
Width
2.8 in.
7.1 cm 
CDRH Class
I, II