LS 3070 Product Reference Guide: Programming
Scan Data Transmission Format
Scan data format options can be selected by the user. The following are 
standard selections:
Standard:
<data as is>
Option 1:
<data> <SUFFIX>
Option 2:
<PREFIX> <data> <SUFFIX>
Option 3:
<PREFIX> <data>
<data as is> = scanned bar code data
<PREFIX> and <SUFFIX> as selected by the user
Laser Control 
Laser On Timeout
The maximum time the laser will remain on or decode processing will continue 