Sears 005734-0 Manuale Utente

Pagina di 22
 
 
9
Figure 13 - Grounding the Generator
Proper grounding of the generator will help prevent electrical shock 
in the event of a ground fault condition in the generator or in connected 
electrical devices. Proper grounding also helps dissipate static electricity, 
which often builds up in ungrounded devices.
2.4.2  CONNECTING ELECTRICAL LOADS
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 
3-phase loads to the generator. DO NOT connect 50 Hz loads to the 
generator.
Let engine stabilize and warm up for a few minutes after starting.
• 
Plug in and turn on the desired 120 or 240 Volt AC, single phase, 60 
• 
Hz electrical loads.
Add up the rated watts (or amps) of all loads to be connected at 
• 
one time. This total should not be greater than (a) the rated wattage/
amperage capacity of the generator or (b) circuit breaker rating of the 
receptacle supplying the power. See "Don't Overload the Generator" 
below.
2.5  
DON’T OVERLOAD THE 
GENERATOR
Overloading a generator in excess of its rated wattage capacity can result 
in damage to the generator and to connected electrical devices. Observe 
the following to prevent overloading the unit:
Add up the total wattage of all electrical devices to be connected at one 
• 
time. This total should NOT be greater than the generator's wattage 
capacity.
The rated wattage of lights can be taken from light bulbs. The rated 
• 
wattage of tools, appliances and motors can usually be found on a 
data label or decal affixed to the device.
If the appliance, tool or motor does not give wattage, multiply volts 
• 
times ampere rating to determine watts (volts x amps = watts).
Some electric motors, such as induction types, require about three 
• 
times more watts of power for starting than for running. This surge of 
power lasts only a few seconds when starting such motors. Make sure 
to allow for high starting wattage when selecting electrical devices to 
connect to the generator:
1.  Figure the watts needed to start the largest motor.
2.  Add to that figure the running watts of all other connected loads.
The Wattage Reference Guide is provided to assist in determining how 
many items the generator can operate at one time.
NOTE:
All figures are approximate. See data label on appliance for wattage 
requirements.
2.6  WATTAGE REFERENCE GUIDE
  Device  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Running Watts
  *Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
  *Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . 3800
  *Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . 6000
  Battery Charger (20 Amp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Belt Sander (3")  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
  Chain Saw  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Circular Saw (6-1/2")  . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1000
  *Clothes Dryer (Electric)   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5750
  *Clothes Dryer (Gas)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  *Clothes Washer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150
  Coffee Maker  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
  *Compressor (1 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
  *Compressor (3/4 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
  *Compressor (1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
  Curling Iron. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  *Dehumidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650
  Disc Sander (9") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Edge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Electric Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
  Electric Nail Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Electric Range (per element) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
  Electric Skillet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250
  *Freezer . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..700
  *Furnace Fan (3/5 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
  *Garage Door Opener . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 to 750
  Hair Dryer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Hand Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 to 1100
  Hedge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
  Impact Wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
  Iron. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  *Jet Pump  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
  Lawn Mower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
  Light Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
  Microwave Oven. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 to 1000
  *Milk Cooler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100
  Oil Burner on Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
  Oil Fired Space Heater (140,000 Btu)  . . . . . . . . . . . . . . . . . . . . . 400
  Oil Fired Space Heater (85,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . 225
  Oil Fired Space Heater (30,000 Btu)  . . . . . . . . . . . . . . . . . . . . . . 150
  *Paint Sprayer, Airless (1/3 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . 600
  Paint Sprayer, Airless (handheld). . . . . . . . . . . . . . . . . . . . . . . . . 150
  Radio  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 to 200
  *Refrigerator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
  Slow Cooker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
  *Submersible Pump (1-1/2 HP)  . . . . . . . . . . . . . . . . . . . . . . . . 2800
  *Submersible Pump (1 HP)  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
  *Submersible Pump (1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
  *Sump Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1050
9
Section 2 – Operation
Generator Ground Lug