Autostart as-6205 sh Manuale Utente

Pagina di 20
P.20 Installation 
Guide
 AS-6205 SH 
Diagnostics - Parking Lights Flash Rate 
Flashes 
Description 
1
x Doors locked, Starter Kill armed. 
x End of Run Time. 
x
TRUNK
 button pressed 
x
START
 signal received by the Module. 
x Cold Weather Mode cancelled. 
x Cannot start after maximum number of attempts is reached. 
2
x Run Time cancelled. 
x Remote start attempt cancelled by remote. 
x Doors unlocked, Starter Kill disarmed. 
3
x Entering Cold Weather Mode 
4
x +12 volts detected on the Brake line; cranking cancelled 
x Entering Tach Learning 
5
x New Transmitter learnt  
x Tach learnt 
6
x Remote start attempt was made with a Tach or a vacuum signal detected before 
cranking
8
x Unit reset: occurs when the unit is reset to factory defaults 
10
x The Hood Switch line went to ground during cranking or run time 
1 – pause – 
2
x There was an attempt to start the vehicle while the Module was in Valet Mode. 
2 – pause – 
2
x There was an attempt to start the vehicle while the Module was in Home Valet 
Mode. 
ON solid 
Cold Weather Mode: the Brake Pedal is being held down 
ON 2 sec. 
x The Hood is up and the Hood Switch line went to ground. This is step one of the 
Programming Mode 
ON 3 sec. 
x First press of the 
START
button under Safe Start. 
x Entering Home Valet Mode 
ON 4 sec. 
x
LOCK
or
UNLOCK
pulse (if door pulse is configured to 4 sec.) 
ON 25 sec. 
x If the Hood Pin-switch has been pressed twice: the Unit went into step 1 of the 
Programming cycle and no Transmitter activity was detected for 20 seconds 
Or the Unit went into step 1 of the Transmitter Code Learning procedure and no 
activity was detected for a few seconds. The Unit has exited the Transmitter Code 
Learning procedure. 
Irregular 
x If the Module gives irregular flashes (1 to 10 flashes followed by a pause, followed 
by more flashes), it is in Playback Mode. This occurs when the Hood-switch line is 
flashed 3 times. 
Constant 
flashes 
up to 30 sec. 
x Panic Mode set off.