Alliance Laundry Systems d355ie1b Manuale Utente

Pagina di 88
504524
19
(Four-Wire Power Cord)
IMPORTANT: Use only a U.L. listed No. 10 AWG 
(copper wire only) four conductor power supply cord 
kit rated 240 Volts (minimum) 30 Amperes and 
labeled as suitable for use in a clothes dryer unit.
NOTE: The power cord is not supplied with the dryer 
unit when the dryer unit is shipped from the factory, 
therefore, disregard steps 2 and 3 below when 
connecting a four-wire power cord to a new dryer 
unit.
If the dryer unit has a three-wire cord attached, then 
complete steps 1 through 12.
1. Remove the screw holding the access plate to the rear 
of the dryer unit cabinet.
2. Remove the three screws holding the three wires to 
the terminal block terminals. Save these screws.
3. Loosen the strain relief screw and pull the cord or 
wires out through the rear of the dryer  unit.
4. Remove the terminal bracket ground screw holding 
the ground wire to the terminal block mounting 
bracket. Save the screw.
NOTE: ON NEW DRYER UNITS, this is the ground 
wire that goes from the neutral (center) terminal on 
the terminal block to the mounting bracket.
Install four-wire power cord
5. Route the end of the four-wire power cord through 
the strain relief. DO NOT tighten the strain relief 
screws at this time.
6. Insert the end of power cord and strain relief through 
the hole in the rear of the dryer unit cabinet. Install 
the strain relief nut from the inside of the cabinet and 
tighten firmly.
7. Attach the green ground wire (from the four-wire 
power cord) to the terminal block mounting bracket 
using the hex head screw removed in Step 4. Tighten 
the screw firmly.
8. Using the three wire-binding (10-32x3/8") screws 
from the accessories envelope located inside the 
cylinder
 (unless the screws were previously removed 
in Step 2), attach the power cord wires to the terminal 
block terminals as follows:
a. Red to Red
b. Black to Black
c. White to White (see NOTE below)
NOTE: When installing the white wire, loop the free 
eyelet end of the ground wire (from Step 4) and place 
it together with the white wire and attach both wires 
to the neutral (center) terminal on the terminal block. 
See following page.
IMPORTANT: Failure to tighten the nuts firmly on 
the terminal block may result in power cord wire 
failure.
9. Tighten the two strain relief screws to secure the 
power cord.
10. Recheck all screws to be sure they are tight.
11. Check the continuity of the ground connection before 
plugging the cord into an outlet. Use an acceptable 
indicating device connected to the center grounding 
pin of the plug and the green screw on the back of the 
cabinet. See illustration on following page.
12. Reinstall the access plate and screw to the rear of the 
dryer unit cabinet.
To reduce the risk of electrical shock, 
disconnect the electrical power to the dryer 
unit before proceeding.
W151
WARNING
STRAIN 
RELIEF
NUT
TYPICAL
FOUR-WIRE
RECEPTACLE
STRAIN
RELIEF
D006IE1C
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
120 ± 12
V.A.C.
240 ± 12
V.A.C.
POWER CORD -
NOT SUPPLIED
WITH DRYER
(Four-Wire)