Alliance Laundry Systems d355ie1b Manuale Utente

Pagina di 88
504524
23
Gas Requirements . . .
(Gas Dryers)
NOTE: The gas service to a gas dryer unit must 
conform with the local codes and ordinances, or in the 
absence of local codes and ordinances, with the latest 
edition of the National Fuel Gas Code ANSI Z223.1/
NFPA 54 or the CAN/CGA-B149, National Gas 
Installation Code.
Natural Gas, 1,000 Btu/ft
3
 (37.3 MJ/m
3
), service must 
be supplied at 6.5 ± 1.5 inch water column pressure.
For proper operation at altitudes above 2,000 feet (610 m) 
the natural gas valve spud orifice size must be reduced to 
ensure complete combustion. See table at right.
L.P. (propane) Gas, 2,500 Btu/ft
3
 (97.1 MJ/m
3
), service 
must be supplied at 10 ± 1.5 inch water column pressure.
NOTE:  DO NOT connect the dryer unit to L.P. 
(propane) Gas Service without converting the gas 
valve. A 458P3 L.P. (propane) Gas Conversion Kit 
must be installed by the Manufacturer’s Authorized 
Dealers, Distributors, or local service personnel.
NOTE:  The dryer unit and its individual shut-off 
valve must be disconnected from the gas supply 
piping system during any pressure testing of that 
system at test pressures in excess of 1/2 psi (3.45 kPa). 
The dryer unit must be isolated from the gas supply 
piping system by closing its individual manual shut-off 
valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 
1/2 psi (3.45 kPa)
NOTE:  When connecting to a gas line, an equipment 
shutoff valve must be installed within 6' (1.8 m) of the 
dryer. An 1/8" N.P.T. pipe plug must be installed as 
shown. See illustration.
Altitude
Orifice Size
Part
Number
ft
m
#
Inches
mm
2000
610
41
0.0960
2.44
503776
3000
915
42
0.0935
2.37
503777
5500
1680
43
0.0890
2.26
503778
7000
2135
44
0.0860
2.18
58719
9000
2745
45
0.0820
2.08
503779
10500
3200
46
0.0810
2.06
503780
To reduce the risk of gas leaks, fire or 
explosion:
• The dryer unit must be connected to the 
type of gas as shown on nameplate located 
in the door recess.
• Use a new flexible stainless steel 
connector.
• Use pipe joint compound insoluble in LP 
(propane) Gas, or Teflon tape, on all pipe 
threads.
• Purge air and sediment from gas supply 
line before connecting it to the dryer unit. 
Before tightening the connection, purge 
remaining air from gas line to dryer unit 
until odor of gas is detected. This step is 
required to prevent gas valve 
contamination.
• Do not use an open flame to check for gas 
leaks. Use a non-corrosive leak detection 
fluid.
W154R2
WARNING
D233IE2E
3/8" NPT
GAS CONNECTION
1/8" NPT
PIPE PLUG
(For checking
inlet gas pressure)
NEW 
STAINLESS
STEEL
FLEXIBLE
CONNECTOR
 USE ONLY 
IF ALLOWED 
BY LOCAL
CODES 
(Use
Design A.G.A.
Certified
Connector)
EQUIPMENT
SHUT-OFF
VALVE
Installed within 
6' (1.8 m) of dryer
                 BLACK IRON PIPE
Shorter than 20' (6.1 m) - use 3/8" pipe
Longer than 20' (6.1 m) - use 1/2" pipe