6.4.3 RECALLING PLU’S MANUALLY 
 
  To  recall  the  PLU  values  the  user  should  first  select  either  local  or 
remote  scale  as  the  tare  value  stored  will  be  specific  to  the  scale 
selected. 
 
  Then press the [PLU] key, enter the PLU number (00 – 99) then press 
the [PLU] key again to recall the data. 
 
  The display will show the results of the recall for 1 second then return 
to weighing with the data in place.   
 
          For example: 
 
 
 
 
 
 
 
 
 
 
 
 
 
  If  the  [PLU]  key  is  held  down  after  the  numeric  entry,  it  will  show  the 
description as long as the key is pressed.  
 
  In  this  example  the  display 
“PLU  27  ”    “M  4      Nut“    “Brass          “
    shows  the 
description for 1 second, if no data is stored then it will show  
nO   
”   “ 
PLU
  “   “
SAVE
    “. 
 
  If  the  tare  value  is  outside  the  range  permitted  for  the  selected  scale 
(For  example,  if  the  local  scale  is  selected  whereas  the  tare  value 
applies to the remote scale, this would exceed the capacity of the local 
scale) the “Weight” display would show zero tare weight.   
 
  If  the  tare  value  stored  does  not  match  the  increment  of  the  selected 
scale (For example, storing -1.446 for a scale with d=0.05) then round 
the tare weight depending on the scale resolution (For example, in this 
case, -1.45 would be used as the tare value). 
 
ACTIONS 
DISPLAYS 
Press [PLU] 
“PLU  ”       
 
“    - -“
 
“         “ 
Press [2][7] 
“PLU  ”    
“    27”    
“         “ 
Press [PLU] 
“PLU 27 ”  
 
“M 4   Nut“  
 
“Brass     “
 
After 1 second, it will return to 
normal weighing with the Tare 
and Unit Weight previously 
entered. 
 
“     x x x x“
 
“ x x x x  ”   
 
    “         x x“