A basic introduction to the Relay 
What is a relay? 
A device that responds to a small current or voltage change by activating switches or other devices 
in an electric circuit. An electromagnetic switch, remote-controlled switch, a switching device.  
Why are Relays used? 
Relays can have several purposes in remote car starter installations. They are used mainly for 
isolation, inversion, interruption, strengthening current, and for powering multiple wires from one 
source SAFELY
.  
How does it work? 
The basic relay consists of a coil and a set of contacts. The most common relay mechanism is 
electromagnetic. When voltage is applied to the coil, current passes through the wire and creates a 
magnetic field. This magnetic field pulls the contacts together and holds them there until the current 
flow in the coil has stopped.  
Relays come in all varieties and types, but for the applications that concern us, we will concentrate 
on the Single Pole Double Throw (SPDT) 12 Volts relay. 
Naming Convention: 
Usually the relay’s manufacturer will include an electrical diagram on the relay displaying the role of 
each terminal and how they interact with each other. These terminal numbers are standard, and 
can be used with any SPDT relay. 
85 & 86: The Coil. These inputs energize the coil when one is +12 Volts, and the other is Negative. 
They are usually non-polarized, so it does not matter which one is positive (+) or negative (-).  
87: Normally Open (N/O). When the coil is energized, 87 is connected to 30. 
87A: Normally Closed (N/C). When the coil is at rest, 87A is connected to 30.  
30: Common. When the relay is at rest, 30 is connected to 87A. When the coil is energized, it is 
then moved and makes contact with 87 (note: in a SPDT relay, 30 can never be connected to 87 
and 87A at the same time; 30 is connected to either 87 OR 87A) 
What happens:  
When there is no voltage across the COIL (terminals 85 and 86), the relay's movable contact ARM 
(connected to terminal 30) is held, by SPRING tension, against terminal 87a (normally closed 
circuit). 
When 12 volts is applied to the COIL (terminals 85 and 86), the ARM (connected to terminal 30) is 
pulled in by the electromagnet (COIL) so that it physically connects to terminal 87 (normally open 
circuit)  
Remember, there is no polarity on a relay’s coil. This means that you may apply positive from the 
battery to either terminal 85 OR 86, and then Ground the OTHER terminal to activate the relay. In 
other words, you may use either a positive or negative trigger to energize the relay. 
Keep in mind that when the relay is energized, if the positive OR the ground connection on the coil 
is broken, the ARM switches the connection between 30 back from 87 to 87a. 
Quenching Diodes:  
It was said earlier that you energize a relay by applying positive from the battery to either 85 OR 86 
and grounding the other terminal. This is not absolutely true: some relays are “polarized” if they 
have a quenching/suppression diode (a diode installed between the coil terminals 85 and 86, could 
be internal or external). To activate the coil on this type of relay, make sure that the +12 Volts 
trigger is on the same terminal of the relay as the Cathode (- or striped side) of the