L O C A T I O N   I N   C O U N T E R T O P
A)
Minimum flat countertop surface. Must be
equal to or greater than cooktop width.
B)
Minimum 2" (51) wide clearance from the
cooktop side edge to any combustible
surface up to 18" (457) above the cooktop
(noted by shaded area).
C)
Minimum 2" (51) wide clearance from the
cooktop side edge to any combustible
surface up to 18" (457) above the cooktop
(noted by shaded area).
O V E R H E A D   C A B I N E T   D I M E N S I O N S
D)
Minimum spacing between cabinets directly
over cooktop must be greater than or equal
to the nominal width of the cooktop unit(s).
E)
Minimum 18" (457) vertical distance from
the countertop surface to the bottom of
cabinets adjacent to the cabinet directly
above the cooktop unit.
F)
Minimum 24" (610) clearance between top
of countertop and bottom of wood or metal
cabinet which is protected by not less than
1
/
4
" (6) flame retardant millboard covered
with not less than No. 28 MSG sheet steel,
.015" (.4) stainless steel, or .024" (.6)
aluminum or .02" (.5) copper. Minimum
30" (762) clearance between the top of the
countertop and the bottom of an unpro-
tected wood or metal cabinet.
G)
Minimum 0" (0) from rear wall.
H)
Maximum 13" (330) depth of overhead
cabinets directly above and within side wall
clearances. 
S I T E
P R E P A R A T I O N
IMPORTANT NOTE: Installation of the Wolf
electric cooktop must meet the following
location requirements. All dimensions listed
are minimum requirements for safe operation.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the risk
can be reduced by installing a ventilation
hood that protects horizontally a
minimum of 5" (127) beyond dimension H
on overhead cabinets.
Failure to locate the cooktop unit
without the proper clearances will result
in a fire hazard.
D
H
E
A
B
C
F
G
Minimum clearances for installation