Adam Equipment cbw-6a Manuale Utente

Pagina di 28
 
 
 
CBWa Scales only: 
 
The CBWa scales can change units from kilograms to grams, pounds or pounds/ounces
immediately if they are enabled as in the step above.  This also allows the scales to be 
calibrated in either kilograms or pounds and all memory accumulations are in either 
kilograms or pounds as last selected.  
When the scales are set to display in other units the accumulation function is 
still keeping the weight in kilograms (or pounds for the CBWa  series) in 
memory and will use the base weighing unit when printing over the RS-232 
interface.   
 
7.7  SETTING OF THE CHECK WEIGHING ALARM  
 
•  The display will show “bEEP x” where “x” is a digit from 0 to 2. 
 
0
 
will set the buzzer to off when check weighing 
1
 
will set the buzzer to on when the OK symbol is on 
2
 
will set the buzzer to on when the weight is outside 
the OK symbol limit 
 
•  To change this digit press the [Tare/Ï] key. 
 
• Press the [Zero/Enter] key to store the changed value and 
continue to the next parameter. 
 
 
7.8  SPEED AT WHICH THE MACHINE WILL RUN THE ADC 
 
•  The slowest setting is 7.5 and the fastest is 60. The default setting 
is usually 15. The display will show “SPd  15”. 
 
•  To change this setting press the [Tare/Ï] key. 
 
• Press the [Zero/Enter] key to store the changed value and return 
to the normal weighing. 
 
© Adam Equipment Company 2007 
17