Adtran MX2800 M13 Manuale Utente

Pagina di 200
9-28    
61200290L1-1G
Section 9, Transaction Language 1 (TL1)
MX2800 M13 Multiplexer User Manual
DIAGLPBKTIMEOUT
ENUM
One of the following:
• DISABLE
• 1-MIN
• 5-MINL
• 10-MIN
• 15-MIN
• 30-MIN
• 45-MIN
• 1-HR
• 2-HR
Identifies the amount of time before a 
Diagnostic Loopback will time out
• DISABLE - timeout is disabled
• 1-MIN - timeout value is one minute
• 5-MINL - timeout value is five minutes
• 10-MIN - timeout value is ten minutes
• 15-MIN - timeout value is 15 minutes
• 30-MIN - timeout value is 30 minutes
• 45-MIN - timeout value is 45 minutes
• 1-HR - timeout value is 60 minutes
• 2-HR - timeout value is 120 minutes
DIAGRESET
Y/N
Y or [N]
Resets Diagnostic Loopbacks
• Yes (Y) - reset the diagnostic loopback
• No (N) - do not reset the diagnostic 
loopback
PSBATTERYLOWRLY
Y/N
Y or [N]
Identifies status of Power Supply Battery 
Low alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
PSCHARGERFAILRLY
Y/N
Y or [N]
Identifies status of Power Supply Charger 
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
PSFANFAILRLY
Y/N
Y or [N]
Identifies status of Power Supply Fan Fail 
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
PSMALFNCRLY
Y/N
Y or [N]
Identifies status of Power Supply 
Malfunction alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
PSPOWERFAILRLY
Y/N
Y or [N]
Identifies status of Power Supply Power 
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
Table 9-9.  TL1 Editing Data Dictionary for EQPT (Continued)
Keyword
Type
Domain
Description