ATTO Technology 2400c-r-d Manuale Utente

Pagina di 51
26
•  Flow Control: None
•  Terminal type: ASCII
•  Echo: on
 f. Click 
OK.
4
After you connect to the Fibre Bridge, start-up 
messages are displayed. These messages are 
only displayed at start-up. The last line in the 
start-up message sequence is 
Ready
5
In serial port sessions, there is no prompt on 
the line below the word 
Ready. Begin typing 
commands in the blank line where the cursor is 
resting. No user name or password is required 
for serial port access.
6
To verify that you have connected successfully, 
type 
help after the Ready prompt and press 
Enter.
•  If a list of all available commands does not 
appear on the screen, review the steps in this 
section, check the cable, or contact service 
personnel until the problem is solved. 
If you have difficulty using the serial port, verify that 
you have the correct settings and that your serial cable 
is less then two meters in length.
Using Telnet
Up to three Telnet sessions can be conducted 
simultaneously. A serial port session can use the CLI 
while Telnet sessions are open. Whichever session 
issues the first set CLI command can continue to issue 
set commands, while the other sessions can only issue 
get commands or display information. Once a 
connection is established, refer to 
1
Connect to the Fibre Bridge from a computer on 
the same Ethernet network.
2
Start a Telnet session. 
Note
There is more than one way to connect to the 
Fibre Bridge using a telnet program.Your 
telnet program may operate differently than in 
the following instructions.
3
At the telnet prompt, issue the 
open command 
where x.x.x.x is the IP address of the Fibre 
Bridge.
telnet > open x.x.x.x
4
If you have to specify a port type, enter the port 
type “telnet” and the terminal type “vt100”.
port type: telnet
terminal type: vt100
5
Enter the default values for the user name, 
root, and the password, Password, if you did 
not set new values in