Honeywell CM907 Manuale Utente

Pagina di 18
16
17
Tr
oub
leshooting Guide
Symptom
CM907 has a blank LCD  scr
een
CM907 shows a flashing 
 
symbol on the LCD scr
een
The CM907’
s LCD scr
een 
works but the heating does  not switch on
Heating switches ON or OFF  too slowly or quickly
Temperatur
e swings between 
too hot and too cold.
CM907 shows a flashing 
 symbol on the LCD 
scr
een
P
ossib
le Cause
Batteries not installed
Incorr
ect batter
y orientation
Exhausted batteries
Batteries ar
e exhausted and 
need r
eplacing
No power to heating system
Pr
ogram does not call for 
heat
CM907 not connected to  boiler pr
operly
CM907 not set corr
ectly for 
your system
CM907 not set corr
ectly for 
your system
Fault in CM907
Remed
y
Check to see if ther
e ar
e batteries in the batter
compar
tment and the paper tab has been r
emoved
Check that the batteries have been installed in the  corr
ectorientation
Replace with new batteries
Replace with new batteries 
Check that ther
e is power to the heating system.
Move the slider switch to 
MAN 
and pr
ess 
 
 or to 
incr
ease the temperatur
e a few degr
ees above the 
curr
ent r
oom temperatur
e. The heating should come 
on after a few seconds.
Call installer to check electrical connection between  the CM907and the boiler
.
Call Installer
Call Installer
Remove and r
e-inser
t the batteries in the CM907. 
If the 
 symbol does not clear itself in a few 
minutes call the installer