Pfaff 1246 Manuale Utente

Pagina di 36
 
 
Setting up
 
27
Fig. 9 - 04
Fig. 9 -03
1
2
Switch the machine off!
Danger due to unintentional 
starting of the machine!
Removing the bobbin case:
 
● Open the bed slide.
 
● Raise latch 1 and remove bobbin 
case 2.
Inserting the bobbin case.
 
● Insert bobbin case 2 so that it clicks into  
place.
 
● Close latch 1 and close the bed slide.
Do not operate the machine when the hook compartment cover is open!
Danger of injury from moving parts!
9
.04 
Threading the bobbin thread and regulating the bobbin thread tension
Switch the machine off!
Danger due to unintentional 
starting of the machine!
 
● Thread the bobbin as shown in Fig. 9-04.
 
● When the thread is pulled, the bobbin 
must rotate as shown by the arrow.
 
● Regulate the bobbin thread tension on 
srew 1.
9
.03 
Removing/Threading the bobbin case