culligan h30 Manuale Utente

Pagina di 16
INSTALLATION
This Owner’s Guide provides visual assembly reference only. Since specialized
skills are required in the assembly of the drinking water system, we recom-
mend that you contact your local independently operated Culligan dealer to
complete this installation.
APPLICATION GUIDELINES
The Good Water Machine
 is designed for use on potable water supplies
meeting the guidelines outlined in Table 1.  The system should be installed on
your home’s cold water line.  The flushing stream should discharge through
an approved siphon break as illustrated in Figure 1.  Installation of this system
must comply with state and local laws and regulations.
5
TABLE 1
Influent Water Characteristic
Pressure
40 - 120 psi (280 - 827 kPa)
Temperature
33 - 100°F (1 - 38°C)
Total Dissolved Solids (TDS)
1
0 - 4000 ppm ( 0 - 4000 mg/L)
pH
5 - 10
Chlorine
2
0 - 3 ppm ( 0 - 3 mg/L)
Chloramine
0 - 3 ppm ( 0 - 3 mg/L)
Turbidity
0 - 10 NTU
Iron
0 - 1 ppm (0 - 1 mg/L)
Bacterial Quality
Potable
1
See the Technical Manual for all applications where TDS exceeds 1000 ppm (1000 mg/L).
A booster pump is strongly recommended.
2
The reverse osmosis membrane filter used in this system may be damaged by chlorine.
This system includes activated carbon which protects this element by reducing chlorine.
Influent chlorine should not exceed 3 mg/L.