Garmin G1000 Annunciations and Alerts Pilot’s Guide for Mooney M20M & M20R
9-12
ANNUNCIATIONS & ALERTS
GIA 63 Message Advisories
Alerts Window Message
Comments
GIA1 CONFIG – GIA1 configuration 
error.  Config service req’d. 
The GIA1 and/or GIA2 configuration settings do not match backup configuration 
memory.  The G1000 system should be serviced.
GIA2 CONFIG – GIA2 configuration 
error.  Config service req’d.
GIA1 COOLING – GIA1 temperature 
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly.  Allow units to 
warm up to operating temperature.
GIA2 COOLING – GIA2 temperature 
too low.
GIA1 COOLING – GIA1 over tempera-
ture.
The GIA1 and/or GIA2 temperature is too high.  If problem persists, the G1000 
system should be serviced.
GIA2 COOLING – GIA2 over tempera-
ture.
GIA1 SERVICE – GIA1 needs service.  
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a problem in the unit.  The G1000 
system should be serviced.
GIA2 SERVICE – GIA2 needs service.  
Return the unit for repair.
MANIFEST – GIA1 software mismatch.  
Communication halted.
The GIA1 and/or GIA 2 has incorrect software installed.  The G1000 system should 
be serviced.
MANIFEST – GIA2 software mismatch.  
Communication halted. 
COM1 TEMP – COM1 over temp.  
Reducing transmitter power.
The system has detected an over-temperature condition in COM1 and/or COM2.  The 
transmitter is operating at reduced power.  If the problem persists, the G1000 system 
should be serviced.
COM2 TEMP – COM2 over temp.  
Reducing transmitter power.
COM1 SERVICE – COM1 needs 
service.  Return unit for repair.
The system has detected a failure in COM1 and/or COM2.  COM1 and/or COM2 may 
still be usable.  The G1000 system should be serviced when possible.
COM2 SERVICE – COM2 needs 
service.  Return unit for repair.
COM1 PTT – COM1 push-to-talk key 
is stuck.
The COM1 and/or COM2 external push-to-talk (PTT) switch is stuck in the enable (or 
“pressed”) position.  Press the PTT switch again to cycle its operation. 
If the problem persists, the G1000 system should be serviced.
COM2 PTT – COM2 push-to-talk key 
is stuck.