REMOVING THE FOOT AND CALF MASSAGER
1.  Lift the foot and calf massager up, then place a box or other sturdy object beneath it
  for support.  
2.  Locate the air pump on the bottom of the chair, then remove the six sets of screws/washers  
  that secure the pump to the chair (Fig. 1).
3.  Locate the connector box on the bottom left side of the chair, near the foot and calf  
  massager (Fig.2).
4.  Using a Phillips-head screwdriver, remove the two screws that secure the connector box cover,  
  remove the cover, then disconnect the red connector.
5.  Cut any zip ties that secure the cable that runs from the connector box to the foot and calf  
  massager, to free the cable from the chair base.   
6.  Remove the box or other sturdy object that is supporting the foot and calf massager,  
  allowing the massager to drop down to a vertical position.
7.  Standing in front of the foot and calf massager, detach the upholstered flap that covers the  
  massager frame
 
(Fig.3)
.
  
  NOTE: It is helpful to flip the upholstered flap up onto the seat cushion and place an object on  
  top of it to hold it out of the way.
Tools Required: Nail clipper or other instrument suitable for cutting zip ties, Phillips-head screwdriver, flat-head 
screwdriver, vice grip, small hammer.
NOTE: SAVE ALL SCREWS FOR USE DURING REASSEMBLY.
REPLACING THE FOOT AND CALF MASSAGER
HT-7120
 
March 14, 2012
(Fig.3)
(Fig.2)
1
Screw/washer
Air pump
(Fig.1)
To  ensure that Human Touch
®
 products are repaired in a manner that is fully consistent with the practices used during the manufacturing process, Human Touch requires that all 
product repairs are performed using only factory-new parts and in accordance with these product repair instructions.
SERVICE LEVEL: 3