INSTEON 2842-222 Manuale Utente

Pagina di 4
 
2452-222/2452-422/2452-522 Rev. 11/6/2012 1:27 PM / See Owner’s Manual for Warranty Information. 
Protected under U.S. and foreign patents (see www.insteon.com
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845 
 
 
 
Sensor won’t control 
linked responders 
a) Make sure LED flashes to confirm it has power and is sensing motion 
b) Sensor is in night-only mode (and it is “day”) 
c) Move a dual-band INSTEON device (e.g., Access Point) closer to the Motion Sensor 
d) Sensor is in its 1 minute countdown 
LED flashing rapidly 
after motion is 
detected 
Sensor did not receive an acknowledgement from one or more linked devices. If this occurs 
repeatedly you may need to move a dual-band INSTEON device closer to the Sensor or you may 
need to unlink a device which is no longer in use in your home. If the INSTEON responders are no 
longer available, you may either use software or perform a factory reset to remove the unwanted links. 
LED not flashing 
upon motion 
a) You may need to wait up to 8 seconds to see the flash 
b) Battery may need to be replaced 
Not sensing motion 
a) Light detected and unit is in night-only mode 
b) Motion Sensor aimed too low 
c) Temperature too high, or low (sensor needs to be able to distinguish between what is being sensed 
and its surroundings 
d) See Placement Tips section 
LED is double 
flashing upon motion 
Low battery warning—replace with fresh battery 
 
Remove Motion Sensor as a Controller 
1)  Press and hold the set button on Motion Sensor for 5 seconds 
Motion Sensor LED (behind sensor lens) will start blinking red 
2)  Press and hold the set button on Motion Sensor for 5 seconds  
Motion Sensor LED will continue blinking red
 
3)  Press and hold the responder set button until it beeps 
Motion Sensor LED will stop blinking
 
4)  Test by tapping the set button on Motion Sensor 
Former responder will not respond
 
Factory Reset 
Return Motion Sensor to Factory Settings 
1)  If possible, remove Motion Sensor as a controller of all responders before proceeding* 
2)  Remove battery 
3)  Wait 15 seconds 
4)  While pressing the set button, reattach the battery 
After about 2 seconds the LED will turn on
 
5)  Continue pressing the set button for 5 seconds and then release the set button.  
The LED will turn off after about 2 seconds 
 
* If you do not unlink, your responder will to continue to respond to Motion Sensor even after factory reset procedure is complete. 
Owner’s Manual and Tech Support 
For the most up-to-date Quick Start Guide visit 
Call: INSTEON Support Line at 866-243-8022 
FCC and IC Warnings 
This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful 
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. 
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes: (1) l'appareil ne doit 
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 
CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a 
transformer-supplied appliance. 
Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne 
pas installer pour commader une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.