Genelec 8040A Manuale Utente

Pagina di 6
Treble tilt control
Treble tilt (third switch group from the left)  
allows adjusting the treble response above  
5 kHz by +2, -2, or -4 dB, which can be used 
for  correcting  an  excessively  bright  or  dull 
sounding system. 
An  acoustic  measuring  system  such  as 
MLSSA  or  WinMLS  is  recommended  for 
analyzing  the  effects  of  the  adjustments, 
however, careful listening with suitable test 
recordings can also lead to good results if a 
test system is not available. Table 1 shows 
some typical settings in various situations. 
Figures 8 and 10 show the effect of the con-
trols on the anechoic response.
Always  start  adjustment  by  setting  all 
switches  to  "OFF”  position. Then  set  only 
one switch per group to the "ON" position to 
select the desired adjustment. If more than 
one switch is set to "ON" (within one switch 
group) the attenuation value is not accurate.
Measure or listen systematically through 
the different combinations of settings to find 
the best frequency balance. 
Maintenance
No user serviceable parts are to be found 
within the loudspeaker cabinet or the ampli-
fier  unit.  Any  maintenance  or  repair  of  the 
loudspeaker should only be undertaken by 
qualified service personnel. 
Safety considerations
Although the 8040A and 8050A have been 
designed  in  accordance  with  international 
safety standards, to ensure safe operation 
and to maintain the loudspeaker under safe 
operating conditions, the following warnings 
and cautions must be observed:
1.  Servicing  and  adjustment  must  only 
  be  performed  by  qualified  service  
  personnel. The loudspeaker must not be 
  opened.
2.  Do  not  use  this  product  with  an 
  unearthed mains cable as this may lead to 
  personal injury.
3. To prevent fire or electric shock, do not 
  expose  the  unit  to  water  or  moisture.  Do 
  not  place  any  objects  filled  with  liquid, 
  such as vases on the loudspeaker or near 
   it. 
4.  Note  that  the  amplifier  is  not  
  completely  disconnected  from  the  AC  
  mains  service  unless  the  mains  power 
  cord is removed from the amplifier or the 
  mains outlet.
5. Free flow of air behind the loudspeaker  
  is necessary to maintain sufficient cooling. 
  Do  not  obstruct  airflow  around  the  
  loudspeakers.
WARNING! 
Genelec 8040A and 8050A loudspeakers are 
capable of producing sound pressure levels 
in excess of 85 dB, which may cause perma-
nent hearing damage.
8040A Accessories
 
 
 
Order code 
Floor stand black 
 
8000-400 
Wall mount black (Omnimount)  8040-404-B 
Ceiling mount black  
 
8040-405-B 
(Omnimount) 
Wall mount black (K&M)   
8000-401 
Soft carrying bag for two   
8040-420 
monitors 
8050A Accessories
 
 
 
Order code 
Floor stand black 
 
8000-400 
Wall mount black (Omnimount)  8050-404-B 
Ceiling mount black  
 
8050-405-B 
(Omnimount) 
Soft carrying bag for one  
8050-420 
monitor 
Table 1. Suggested tone control settings in some typical situations
Speaker Mounting Position
Treble tilt
Bass tilt
Bass roll-off
Desktop LF
Flat anechoic response
None
None
None
None
Free standing in a damped 
room
None
-2 dB
None
None
Free standing in a  
reverberant room
None
-4 dB
None
None
Near field on a reflective 
surface
None
-2 dB
None
-4 dB
In a corner
None
-4 dB
-4 dB
None
Figure 4. The Iso-Pod™ can also be attached to the side of the enclosure for 
horizontal mounting.
Figure 7. Carrying bag for a pair of 8040A loudspeakers.
Figure 5. Omnimount type  
wall mount
Figure 6. K&M type  
wall mount