Hoshizaki F-300BAF Manuale Utente

Pagina di 50
46
8) Remove the thumbscrews attaching spout 
(A) to the evaporator assembly and lift off 
spout (A) and spout packing (A). See Fig 4.
9) Pour the cleaning solution over the 
extruding head until the evaporator 
assembly and the reservoir are filled and 
the solution starts to overflow into the drain 
pan. 
Note: If there is excess scale on the extruding head, fill the evaporator assembly and 
reservoir as described above, then use a clamp on the reservoir hose between 
the reservoir and evaporator assembly to block flow. Pour additional cleaning fluid 
over the extruding head until the evaporator assembly is completely full.
10) Using the thumbscrews, replace spouts (A) and (B) and spout packings (A) and (B) in 
their correct positions.
11) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp 
on the reservoir hose in step 9, remove it before operation.
1) Move the flush switch to the "ICE" position, then turn on the power supply. Replace the 
top panel and the front panel in their correct positions. Make ice using the solution until 
the icemaker stops making ice.
13) Remove the front panel.
14) Move the flush switch to the "FLUSH" position to drain the remainder of the solution.
15) After the solution is drained, move the flush switch to the "ICE" position.
16) Replace the front panel in its correct position.
17) Open the water supply line shut-off valve, and supply water to the reservoir.
18) When the gear motor starts, remove the top panel and front panel. Turn off the power 
supply.
19) Drain out all water from the water line. See 4) through 6).
3. Sanitizing Solution
Dilute .5 fl. oz. (74 ml or 5 tbs) of a 5.5% sodium hypochlorite solution (chlorine 
bleach) with 5 gallons (19 l) of warm water.   
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after 
dilution.
Thumbscrews
Spout (A)
Evaporator Assembly
Fig. 4
Spout (A) Packing