Problem
Possible cause
Solution
The shaver is not entirely 
clean after I clean it in the Jet 
Clean System.
The cleaning fluid in the cleaning chamber is soiled.
Empty and rinse the cleaning chamber.
The cleaning fluid level is too low. If the fluid volume in 
the cleaning chamber drops below the minimum level 
during the cleaning program, the program aborts.The 
cleaning light and the ‘cleaning chamber empty’ symbol 
flash at intervals and the holder returns to its starting 
position.
Refill the cleaning chamber with cleaning fluid to 
a level between the two lines (see chapter 
‘Cleaning and maintenance’).
You have used another cleaning fluid than the original 
Philips cleaning fluid.
Only use HQ200 Philips Cleaning Fluid.
The Jet Clean System does 
not work when I press the 
on/off button.
The Jet Clean System is not connected to the mains.
Put the small plug in the Jet Clean System and 
put the adapter in the wall socket.
You have not placed the shaver in the Jet Clean 
System properly, so there is no electrical connection 
between the Jet Clean System and the shaver.
Press the shaver tightly into the holder to lock it 
into place.
The shaver is not fully charged 
after I charge it in the charger/
Jet Clean System.
You have not placed the shaver in the charger/Jet Clean 
System properly.
Make sure you press the shaver until it locks into 
place.
RQ1008: The operating time 
of the Jet Clean System is 
suddenly shorter or longer 
than it was earlier.
You have selected another cleaning program. The Jet 
Clean System has three cleaning programs: the eco 
program, the normal program and the intensive program. 
Each of these programs has a different operating time.
Press the up/down button on the Jet Clean 
System to select the cleaning program of your 
preference (see chapter ‘Cleaning and 
maintenance’).
English